Puresilk™’s vertical bi-polar electrode cell is a revolution in cell design.

Click here to learn more

Automatic Self-Cleaning Cells.

The microprocessor automatically reverses the polarity of each electrolytic plate cleaning them completely.

Automatic Low Salt Warning.

This protects the power supply from over-salting and allows salt to be added without switching the chlorinator off. (No fuses, no circuit breakers needed.)

Automatic Memory Save.

If there’s a power failure all information is stored for at least seven days. There are no batteries that can go flat or leak.

24-Hour Boost Mode.

The system can be set to operate at full output for 24 hours then automatically return to normal operation.

Automatic Pump Protection Monitor.

If the pump is starved of water, the CCS switches the pump off to stop it running dry. Timing can be adjusted for different hydraulic conditions and pump types.

Automatic Pump Flush.

Cell power switches off 30 seconds prior to pump switch off to flush the cell and pump of concentrated chlorine. This prevents high chlorine levels corroding pipe work, heat exchangers or in-floor cleaning systems.
The world’s best salt chlorinator just got better

Click here to learn more.

The world’s best salt chlorinator just got better

Automatic Self-Cleaning Cells.
The microprocessor automatically reverses the polarity of each electrolytic plate cleaning them completely.

Automatic Output Limiting.
This protects the power supply from over-salting and allows salt to be added without switching the chlorinator off. [No fuses, no circuit breakers needed.]

Automatic Low Salt Warning.
If salt levels fall below the optimum threshold, the diagnostic display scrolls a message requesting a salt top up.

Automatic Low Salt Stop & Re-Start.
If salt levels fall below the minimum point the cell shuts down and a message scrolls. The cell then continues to re-test and when normal salt levels are restored the cell automatically re-starts.

Automatic Memory Save.
If there’s a power failure all information is stored for at least seven days. There are no batteries that can go flat or leak.

24-Hour Boost Mode.
The system can be set to operate at full output for 24 hours then automatically return to normal operation.

Automatic Pump Protection Monitor.
If the pump is starved of water, the CCS switches the pump off to stop it running dry. Timing can be adjusted for different hydraulic conditions and pump types.

Automatic Pump Flush.
Cell power switches off 30 seconds prior to pump switch off to flush the cell and pump of concentrated chlorine. This prevents high chlorine levels corroding pipe work, heat exchangers or in-floor cleaning systems.

Call us on 1300 POOLS